View online or Download Noco Boost Plus GB40 user guide in PDF files. This manuals tels you about important safety warnings, how to use the GB40 battery jumper box, the button explanation, troubleshooting, technical specifications, and warranty information.
Table of Content in the Noco Boost Plus GB40 User Guide:
The GB40 comes partially charged out of the box and needs to be fully charged prior to use. Connect the GB40 using the included USB Charge Cable to the USB IN port and the USB car charger. It can also be recharged from any USB powered port, like an AC adapter, car charger, laptop and more. The USB IN port is rated at 2.1 Amps to ensure safe and efficient charging of the internal lithium battery. Due to FCC regulations, we recommend not to charge and discharge the unit at the same time. The time to recharge a GB40 will differ based on the discharge level and the power source used. Actual results may vary due to battery conditions.
When recharging, the charge level of the internal battery is indicated by the Charge LEDs. The LEDs will slowly pulse 'On' and 'Off' and become solid until all four Charge LEDs are on. When the battery is fully charged, the Green 100% LED will be solid, and the 25%, 50% and 75% Charge LEDs will turn "Off". From time to time, the Green 100% LED will pulse indicating maintenance charging is occuring.
Carefully read and understand the vehicle owner's manual on specific precautions and recommended methods for jump starting the vehicle. Make sure to determine the voltage and chemistry of the battery by referring to your battery owner's manual prior to using this product. The GB40 is for jump starting 12-volt lead-acid batteries only. Before connecting to the battery, verify that you have a 12-volt lead-acid battery. The GB40 is not suitable for any other type of battery. Identify the correct polarity of the battery terminals on the battery. The positive battery terminal is typically marked by these letters or symbol (POS,P,+). The negative battery terminal is typically marked by these letters or symbol (NEG,N,-). Do not make any connections to the carburetor, fuel lines, or thin, sheet metal parts. The below instructions are for a negative ground system (most common). If your vehicle is a positive ground system (very uncommon), follow the below instructions in reverse order.
Low Voltage Batteries & Manual Override.
The GB40 is designed to jump start 12-volt lead-acid batteries down to 2-volts. If your battery is below 2-volts, the Boost LED will be "Off". This is an indication that the GB40 can not detect a battery. If you need to jump start a battery below 2-volts there is a Manual Override feature, which allows you to force "On" the jump start function. CAUTION.
USE THIS MODE WITH EXTREME CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY. BOTH THE SPARK PROOF AND REVERSE POLARITY PROTECTION FEATURES ARE DISABLED. PAY VERY CLOSE ATTENTION TO THE POLARITY OF THE BATTERY BEFORE USING THIS MODE. DO NOT ALLOW THE POSITIVE AND NEGATIVE BATTERY CLAMPS TO TOUCH OR CONNECT TO EACH OTHER AS THE PRODUCT WILL GENERATE SPARKS. THIS MODE USES VERY HIGH CURRENT (UP TO 1000 AMPS) THAT CAN CAUSE SPARKS AND High Heat IF NOT USED PROPERLY. IF YOU ARE UNSURE ABOUT USING THIS MODE, DO NOT ATTEMPT AND SEEK PROFESSIONAL HELP.
1. Internal Battery Level Indicates the charge level of the internal battery.
2. Error LED Illuminates Red if reverse polarity is detected, or blinks “On” and “Off” when the internal battery temperature is too high.
3. Power Button Push to turn unit "On" & "Off".
4. Power LED Illuminates White when unit is "On".
5. Boost LED Illuminates White when Boost is active. If the unit is connected properly to a battery, the GB40 will automatically detect a battery and go into Boost mode (LED flashes White when Manual Overide feature is active).
6. Manual Override Button To enable, push and hold for three (3) seconds. WARNING: Disables safety protection and manually forces Boost "On". Only for use when a battery is too low to be detected.
7. Light Mode Button Toggles the ultra-bright LED light through 7 light modes: 100% > 50% > 10% > SOS > Blink > Strobe > Off
Error | Reason/Solution |
---|---|
Error LED: Solid Red | Reverse polarity/Reverse the battery connections. |
Error LED: Blinking Red w/Cables Connected Properly | The internal battery is too hot/ Allow the unit to cool. Bring the unit into cooler environment. |
Boost Light Does Not Come On w/Cables Connected Properly | Connected battery is below 2-volts/ Remove all loads, and try again, or use Manual Override Mode. |
Internal Battery | Lithium Ion |
Peak Current Rating | 1000A |
Operating Temperature | -20°C to +50°C |
Charging Temperature | 0ºC to +40ºC |
Storage Temperature | -20ºC to +50ºC (Avg Temp.) |
Micro USB (Input) | 5V, 2.1A |
USB (Output) | 5V, 2.1A |
Housing Protection | IP65 (w/Ports Closed) |
Cooling | Natural Convection |
Dimensions (L x W x H): | 6.7 x 3.2 x 1.7 Inches |
Weight | 2.4 Pounds |